Published: November 2026 | Version: 1.0 | Last updated: November 2026
Applies to: Municipalities that own commercial buildings
Purpose: This bulletin outlines fire prevention and risk mitigation tips to help municipalities reduce the chance of fire and limit damage to municipality-owned commercial buildings
Protecting public assets starts with prevention. Municipality-owned commercial buildings face unique risks, including longer emergency response times, limited water supply in some areas, and wildfire exposure. Following the National Fire Code – 2023 Alberta Edition (NFC(AE)) and FireSmart principles helps reduce the chance of fire and limit damage.
The following tips can help municipalities prevent fires and reduce risk in their commercial buildings.
Key prevention and risk mitigation tips
1. Maintain good housekeeping and routine inspections
- Keep exits, stairwells, corridors, and mechanical rooms free of combustible storage
- Do not block exits or fire doors
- Store flammable and combustible liquids in approved cabinets and only in permitted quantities
- Keep electrical and furnace rooms free of debris, especially combustible liquids and materials
2. Maintain fire protection equipment
- Ensure portable fire extinguishers are present, accessible, and serviced and tagged annually by a qualified technician. The maximum travel distance to an extinguisher is typically 23 to 25 m
- Train staff on fire extinguisher use so they are familiar with proper use and response procedures
- Install parking bollards in front of main gas lines and electrical lines to prevent vehicle or machinery impact
- Test emergency lighting monthly with a short test and annually with a full-duration test
- Inspect and maintain fire alarm, sprinkler, and suppression systems as required by the NFC(AE) and manufacturer standards
- Clean commercial cooking exhaust systems regularly according to NFPA 96, if applicable
3. Electrical and heating safety
- Avoid overloading circuits or using extension cords as permanent wiring
- Keep heating equipment clear of combustibles and service it regularly
- Keep electrical panels closed and secured when they are not being serviced
4. Fire safety plan
- Prepare a fire safety plan and review it annually. NFC(AE) Section 2.8 requires a fire safety plan for many commercial buildings, including those with fire alarm systems, assembly occupancies, or flammable storage
- Include evacuation procedures, staff roles, equipment locations, and fire department notification steps
- Keep a copy of the plan on site
- Coordinate fire drills with your local fire chief
- Clearly define and mark muster points
5. Manage contractor fire risks
Hot work activities such as welding, cutting, grinding, and roofing continue to be a significant source of fire losses. Reduce these risks by:
- Implementing a formal hot work permit process
- Maintaining fire watches during and after hot work
- Obtaining proof of liability insurance from contractors before work begins
- Removing or protecting combustible materials in the work area
6. Emergency preparedness and business continuity
Beyond fire prevention, municipalities should also plan for recovery. Recovery planning should include:
- Procedures for temporarily relocating operations
- Protection and backup of vital records and municipal data
- Up-to-date emergency contact lists for restoration contractors and key service providers
- Post-loss recovery and business continuity planning
7. Rural and wildfire considerations (FireSmart)
- Create and maintain a non-combustible zone, ideally 1.5 m wide, around the building, and reduce flammable vegetation within 10 m
- Clear leaves, needles, and debris from roofs, gutters, and vents
- Ensure clear, unobstructed access for fire apparatus, with adequate road width and overhead clearance
- Use fire-resistant exterior materials where practical, and store outdoor combustibles away from the structure
8. Access and cooperation
- Keep fire department access routes clear year-round
- Install a fire department key box where required for buildings with alarm or suppression systems
- Coordinate with your local fire department or Safety Codes Officer for inspections and plan acceptance
Fire prevention quick checklist
- Exits, stairwells, corridors, and mechanical rooms are free of combustible storage
- Exits and fire doors are not blocked
- Flammable and combustible liquids are stored in approved cabinets in permitted quantities
- Electrical and furnace rooms are free of debris
- Fire extinguishers are accessible and serviced and tagged annually
- Staff are trained on fire extinguisher use
- Emergency lighting is tested monthly and annually
- Fire alarm, sprinkler, and suppression systems are inspected and maintained
- Electrical panels are closed and secured
- A fire safety plan is in place, reviewed annually, and kept on site
- Fire drills are coordinated and muster points are marked
- A hot work permit process is in place for contractors
- Recovery and business continuity plans are in place
- FireSmart measures are maintained around the building
- Fire department access routes are clear year-round
Summary
Regular inspections, staff awareness, and prompt correction of hazards are the most effective defences. Contact your municipal fire service or an accredited Safety Codes Officer for site-specific guidance and to confirm compliance with the current NFC(AE).
Protecting public buildings protects the community.
Questions?
For risk management support, RiskPro credits, inspections, training, and other risk-related inquiries, contact your Risk Advisor or the Risk Team at risk@rmainsurance.com.
This bulletin is provided by RMA Insurance for general information only. It is based on our understanding of current law and practice as of the date of publication and does not constitute legal, engineering, fire safety, or other professional advice, or an interpretation of any insurance policy. Coverage is governed solely by the terms of your policy. Municipalities remain responsible for complying with their legal obligations, including applicable fire code requirements, and any use of this information is at the reader’s discretion. For advice on your specific situation, contact your RMA Risk Advisor, local fire authority, or legal counsel.